2014年1月27日星期一

Latest Microsoft 70-691 of exam practice questions and answers

Don't you want to make a splendid achievement in your career? Certainly hope so. Then it is necessary to constantly improve yourself. Working in the IT industry, what should you do to improve yourself? In fact, it is a good method to improve yourself by taking IT certification exams and getting IT certificate. Microsoft certificate is very important certificate, so more and more people choose to attend Microsoft certification exam.

Some sites provide Microsoft 70-691 exam study materials on the Internet , but they do not have any reliable guarantee. Let me be clear here a core value problem of ITCertKing . All Microsoft exams are very important. In this era of rapid development of information technology, ITCertKing just questions provided by one of them. Why do most people choose ITCertKing? This is because the exam information provided by ITCertKing will certainly be able to help you pass the exam. Why? Because it provides the most up-to-date information, which is the majority of candidates proved by practice.

ITCertKing promise that we will spare no effort to help you pass Microsoft certification 70-691 exam. Now you can free download part of practice questions and answers of Microsoft certification 70-691 exam on ITCertKing. When you select ITCertKing, you can not only pass Microsoft certification 70-691 exam, but also have one year free update service. ITCertKing can also promise if you fail to pass the exam, ITCertKing will 100% refund.

ITCertKing is a good website for Microsoft certification 70-691 exams to provide short-term effective training. And ITCertKing can guarantee your Microsoft certification 70-691 exam to be qualified. If you don't pass the exam, we will take a full refund to you. Before you choose to buy the ITCertKing products before, you can free download part of the exercises and answers about Microsoft certification 70-691 exam as a try, then you will be more confident to choose ITCertKing's products to prepare your Microsoft certification 70-691 exam.

If your budget is limited, but you need complete exam material. Then you can try the ITCertKing's Microsoft 70-691 exam training materials. ITCertKing can escort you to pass the IT exam. Training materials of ITCertKing are currently the most popular materials on the internet. 70-691 Exam is a milestone in your career. In this competitive world, it is more important than ever. We guarantee that you can pass the exam easily. This certification exam can also help you tap into many new avenues and opportunities. This is really worth the price, the value it creates is far greater than the price.

ITCertKing is the best catalyst to help IT personage be successful. Many people who have passed some IT related certification exams used our ITCertKing's training tool. Our ITCertKing expert team use their experience for many people participating in Microsoft certification 70-691 exam to develope the latest effective training tools, which includes Microsoft 70-691 certification simulation test, the current exam and answers . Our ITCertKing's test questions and answers have 95% similarity with the real exam. With ITCertKing's training tool your Microsoft certification 70-691 exams can be easy passed.

Exam Code: 70-691
Exam Name: Microsoft (TS: Windows HPC Server 2008, Developing)
One year free update, No help, Full refund!
Total Q&A: 95 Questions and Answers
Last Update: 2014-01-27

70-691 Free Demo Download: http://www.itcertking.com/70-691_exam.html

NO.1 You plan to develop a parallel application by using Windows HPC Server 2008.
You need to ensure that when the application starts, a parameter value is communicated to each process
in the cluster by using a single call.
Which function should you use?
A. MPI_Send
B. MPI_Bcast
C. MPI_Gather
D. MPI_Reduce
Answer: B

Microsoft test   70-691   70-691   70-691   70-691

NO.2 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
You write the following code segment. (Line numbers are included for reference only.)
01 int rank;
02 MPI_Comm_rank(MPI_COMM_WORLD, &rank);
03 // declaration of variable hostName
04 // code to execute
05
06 std::cout << "hostname of rank " << rank;
07 std::cout << ": " << hostName << "\n";
You need to ensure that a variable named hostName contains the name of the cluster node that the code
runs on.
Which code segment should you add at line 05?
A. char *hostName = getenv("MPI_HOSTNAME");
B. char hostName[MPI_MAX_PROCESSOR_NAME];
int resultlen;
MPI_Get_processor_name(&resultlen, hostName);
C. char hostName[MPI_MAX_NAME_STRING];
int resultlen;
MPI_Comm_get_name(MPI_COMM_WORLD, hostName, &resultlen);
D. char hostName[256];
int resultlen = sizeof(hostName);
if (rank == 0)
{
gethostname(hostName, resultlen);
}
Answer: B

Microsoft demo   70-691 exam   70-691 dumps

NO.3 You plan to develop a parallel application by using Windows HPC Server 2008.
You plan to use a method to control the calculations performed by each individual process.
You need to ensure that different commands can be sent to each process.
Which function should you use?
A. MPI_Send
B. MPI_Bcast
C. MPI_Gather
D. MPI_Reduce
Answer: A

Microsoft   70-691 test   70-691 practice test

NO.4 printf("Pi = %d\n", pi);

NO.5 pi = 4 * total/(commSize * totDarts);

NO.6

NO.7 }

NO.8 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
You write the following code segment. (Line numbers are included for reference only.)
01 MPI_Init(&argc, &argv);
02
03 {
04 // program part for rank 0
05
06 }
06 else
07 {
08 // program part for all other ranks
09 }
10 MPI_Finalize();
You need to ensure that the code in the rank 0 section only executes on the process that has a rank of 0.
Which code segment should you insert at line 02?
A. int size;
MPI_Comm_size(MPI_COMM_WORLD, &size);
if (size > 0)
B. int size;
MPI_Comm_size(MPI_COMM_WORLD, &size);
if (size == 0)
C. int rank
MPI_Comm_rank(MPI_COMM_WORLD, &rank);
if (rank == 0)
D. char hostName[MPI_MAX_PROCESSOR_NAME];
int resultlen;
MPI_Get_processor_name(hostName, &resultlen);
char masterName[] = "rank0";
if (strcmp(masterName, hostName) != 0)
Answer: C

Microsoft   70-691   70-691 exam   70-691

NO.9 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
You write the following code segment that computes an approximation to Pi. (Line numbers are included
for reference only.)
01 static int totDarts = 10000;
02 int numDarts = 0;
03
04 MPI_Comm_size(MPI_COMM_WORLD, &commSize);
05 MPI_Comm_rank(MPI_COMM_WORLD, &commRank);
06
07 for(i = 0; i < totDarts; i++) {
08 x = 2 * (randomNr() - 0.5);
09 y = 2 * (randomNr() - 0.5);

NO.10 ++numDarts;

NO.11 You plan to develop a single program multiple data (SPMD) application by using Windows HPC Server
2008.
You use multiple processes to perform intermediate calculations and to provide the results as a single
number.
You need to ensure that the intermediate results are collected and added together by using a single MPI
function.
Which function should you use?
A. MPI_Send
B. MPI_Bcast
C. MPI_Gather
D. MPI_Reduce
Answer: D

Microsoft test   70-691 exam prep   70-691 test   70-691 demo

NO.12 if(commRank == 0) {

NO.13 You develop a parallel application that will be deployed on a Windows HPC Server 2008 cluster.
The application uses point-to-point communication.
The process that has a rank 0 sends an array of integer values to the rank 1 process by using the
following code segment. (Line numbers are included for reference only.)
01 int values[5];
02 MPI_Send(values, 5, MPI_INT, 1, 42,
03 MPI_COMM_WORLD);
You need to ensure that each receiving process is able to correctly receive the values in the most efficient
manner possible.
Which code segment should you use?
A. int values[5];
int buffer[5];
MPI_Reduce(buffer, values, 5, MPI_INT, MPI_SUM, 1, MPI_COMM_WORLD);
B. int values[5];
MPI_Status status;
MPI_Recv(values, 5, MPI_INT, 0, 42, MPI_COMM_WORLD, &status);
C. int value;
MPI_Status status;
MPI_Recv(&value, 1, MPI_INT, 0, 42, MPI_COMM_WORLD, &status);
D. int values[5];
MPI_Status status;
MPI_Recv(values, sizeof(int), MPI_INT, 0, 42, MPI_COMM_WORLD, &status);
Answer: B

Microsoft questions   70-691   70-691   70-691   70-691

NO.14 You plan to develop a parallel application by using Windows HPC Server 2008.
You need to implement a method that will send different data to each process in a communicator by using
a single call.
Which function should you use?
A. MPI_Send
B. MPI_Gather
C. MPI_Reduce
D. MPI_Scatter
Answer: D

Microsoft answers real questions   70-691   70-691   70-691 braindump   70-691

NO.15 if (x*x + y*y <= 1.0)

NO.16 }
You need to ensure that the total number of numDarts is only available on the process that has a rank 0.
Which code segment should you insert at line 13?
A. MPI_Reduce(&numDarts, &total, 1, MPI_INT, MPI_SUM, 0, MPI_COMM_WORLD)
B. MPI_Allreduce(&total, &numDarts, 1, MPI_INT, MPI_SUM, MPI_COMM_WORLD)
C. MPI_Gather(&numDarts, 1, MPI_INT, &total, 1, MPI_INT, 0, MPI_COMM_WORLD)
D. MPI_Allgather(&numDarts, 1, MPI_INT, &total, 1, MPI_INT, MPI_COMM_WORLD)
Answer: A

Microsoft   70-691 practice test   70-691 original questions
10. You plan to develop a Microsoft Message Passing Interface (MPI) application by using Microsoft
Visual Studio.
You have installed the Microsoft HPC Pack 2008 SDK at C:\Program Files\Microsoft HPC Pack 2008
SDK.
You create a new console application.
You need to ensure that the application compiles for a 64-bit architecture.
Which two tasks should you perform? (Each correct answer presents part of the solution. Choose two.)
A. Set the Import Library property to msmpi.lib.
B. Set the Additional Dependencies property to msmpi.lib.
C. Set the Additional Library Directories property to C:\Program Files\Microsoft HPC Pack 2008
SDK\lib\amd64.
D. Set the Additional Manifest Dependencies property to C:\Program Files\Microsoft HPC Pack 2008
SDK\lib\amd64.
Answer: BC

Microsoft original questions   70-691 braindump   70-691 dumps   70-691 certification training
11. You develop a parallel application by using Microsoft Visual Studio 2008.
You have installed the Microsoft HPC Pack 2008 SDK at C:\Program Files\Microsoft HPC Pack 2008
SDK.
You create a new console application based on Microsoft Message Passing Interface (MPI). You set the
Debugger to Launch property to MPI Cluster Debugger.
You need to ensure that five processes are launched when the application is run in debug mode in Visual
Studio 2008.
Which two tasks should you perform? (Each correct answer presents part of the solution. Choose two.)
A. Set the MPIRun Arguments property to -n 5.
B. Set the Application Arguments property to -n 5.
C. Set the MPIRun Working Directory property to C:\Program Files\Microsoft HPC Pack 2008 SDK\bin.
D. Set the MPIRun Command property to C:\Program Files\Microsoft HPC Pack 2008 SDK\bin\MPIExec.
E. Set the Application Command property to C:\Program Files\Microsoft HPC Pack 2008
SDK\bin\MPIExec.
Answer: AD

Microsoft test   70-691   70-691   70-691 test   70-691 study guide   70-691
12. You create a parallel application by using Microsoft Visual Studio 2008.
The application prints a message to the console of all Microsoft Message Passing Interface (MPI)
processes except for one. The application terminates and displays an error message.
You need to change the code in the application so that the application completes successfully.
Which set of tasks should you include in the application?
A. Include mpi.h
Link to msmpi.lib
Call MPI_Start
Call MPI_Comm_rank
Call MPI_Finalize
B. Include mpi.h
Link to msmpi.lib
Call MPI_Init
Call MPI_Comm_rank
Call MPI_Finalize
C. Include mpi.h
Link to ccpapi.tlb
Call MPI_Init
Call MPI_Comm_rank
D. Include mpi.h
Link to msmpi.lib
Call MPI_Init
Call MPI_Comm_size
Answer: B

Microsoft exam simulations   70-691 exam dumps   70-691   70-691 demo
13. You plan to create a parallel application by using Microsoft Visual C++.
You want to use the Microsoft Message Passing Interface (MPI) library in the application.
You need to ensure that the application can be compiled for both 32-bit and 64-bit platforms. You also
need to ensure that targeting both platforms requires minimum maintenance.
What should you do?
A. Create a separate project for each platform.
B. Create separate solution files for each platform.
C. Create separate custom build rules for each platform.
D. Create a separate build configuration for each platform.
Answer: D

Microsoft   70-691   70-691   70-691
14. You create a Microsoft Message Passing Interface (MPI) application by using Microsoft Visual Studio
2008.
The application process is named MPIApplication.exe. You plan to debug the application by using the MPI
Cluster Debugger in Visual Studio 2008.
You need to attach the debugger to the remote process on a compute node.
Which process should you attach to?
A. smpd.exe
B. mpiexec.exe
C. msvmon.exe
D. MPIApplication.exe
Answer: C

Microsoft study guide   70-691   70-691   70-691   70-691
15. You create a Microsoft Message Passing Interface (MPI) application by using Microsoft Visual Studio
2008.
You plan to debug the application by using Visual Studio 2008.
You need to configure the nodes that will be used for debugging.
What should you do?
A. Use the Cluster Debugger Configuration tool in Visual Studio.
B. Use the debugging pane in the Visual Studio project property pages.
C. Use the configuration pane in the Cluster Administration Console tool.
D. Use the node management pane in the Cluster Administration Console tool.
Answer: A

Microsoft certification training   70-691   70-691 exam   70-691

NO.17 You plan to develop a parallel application by using Windows HPC Server 2008.
The application performs the following tasks:
x Performs multistep calculations
x Processes data by using the same code segment that runs on each compute node
You need to ensure that each compute process executes the same step simultaneously.
Which type of communication should you use?
A. Buffered
B. Collective
C. Non-blocking
D. Point-to-point
Answer: B

Microsoft test   70-691 certification training   70-691 braindump   70-691 exam dumps   70-691   70-691 questions

ITCertKing offer the latest 000-540 exam material and high-quality 00M-229 pdf questions & answers. Our 70-336 VCE testing engine and C-TSCM62-65 study guide can help you pass the real exam. High-quality LOT-958 dumps training materials can 100% guarantee you pass the exam faster and easier. Pass the exam to obtain certification is so simple.

Article Link: http://www.itcertking.com/70-691_exam.html

没有评论:

发表评论